Manual Self-Draining Freeze-Proof Valve Assembly
Keywords:
firefighting equipment
Category:
Self-venting Freeze Protection Valve Assembly
E-mail:
Detailed introduction
Manual Self-Draining Freeze-Proof Valve Assembly – Dedicated for Fire Protection in Petrochemical Enterprises
Underground direct-buried installation, with manual operation above ground. Any remaining water between the external pipeline and the drain outlet of this freeze-proof valve assembly is automatically discharged.
Scope of application:
Firewater and foam mixture network end points in petrochemical enterprises
Function: Manually operated on the ground for opening, closing, and automatic drainage
Product features:
●Quick operation: For the DN100 valve, a 4/5-turn wrench rotation is sufficient; for other sizes, just 3 to 20 turns will fully open or close it.
● Single- or dual-plunger drain valve automatically removes residual water from the chamber above the drain hole after closure, preventing freezing in winter.
● The main valve features pressure-assisted or pressure-reducing sealing, ensuring that sealing and opening forces remain unaffected by system pressure.
● The main transmission components and seals are made from copper alloy and high-quality stainless steel materials, offering excellent rust resistance.
● Extended version with ground operation capability; the outlet features an external pipe connection flange—simple and easy to implement.
● Can be directly buried or installed with individual well structures
●JOTUN paint—guaranteed to last three years without fading, cracking, or peeling.
Main technical specifications
| Model |
ZF100-1.6 |
ZF125-1.6 |
ZF150-1.6 |
ZF200-1.6 |
| Nominal Specification |
DN100PN1.6 |
DN125PN1.6 |
DN150PN1.6 |
DN200PN1.6 |
| Work stress range |
0.5 to 1.6 MPa |
|||
| Outlet connection specification range |
DN80~100 |
DN100~125 |
DN125~150 |
DN150~200 |
| Inlet Flange Specifications |
DN100PN1.6-RF |
DN125PN1.6-RF |
DN150PN1.6-RF |
DN200PN1.6-RF |
| Inlet Flange Standard |
HG/T20592-2009 (GB/T9124.1~2 or ANSI and ASME) |
|||
| Total height range |
0.8–3.5 m, choose as you like |
Choose from 0.9 to 4.5 meters |
||
| Applicable Medium |
Freshwater or neutral water. After special treatment, it can be used for foam concentrates, high-chloride ion water, and seawater. |
|||
Pressure-regulating above-ground gauge-equipped, dual-drainage pressure regulating valve – KB